Audiovox PRO9056 Instrukcja Instalacji Strona 17

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 24
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 16
128-8857b
17 of 24
17
METHOD 2:
To connect to the key in sensor circuit as shown for method 2:
1. Locate the control wire that connects the drivers door pin switch to the key in sensor switch.
2. Cut this wire and connect the ignition cylinder side to chassis ground.
3. Locate the key in sensor switch wire that connects the chime module to the ignition cylinder .
4. Cut this wire and connect the ignition cylinder side to the Remote Start Negative Safety Shut down
Wire Gray/Black, using a 4002 series diode as shown above.
NOTE: A second 4002 series diode may be required to maintain the integrity of the hood open, shut
down circuit. If this is the case, it must be installed as shown in the diagram above. The anode (Non
Striped) side must be connected to the Gray/Black wire of the Remote Start Unit. The cathode (Striped)
side must be connected to the hood pin switch. If the hood pin switch is also used for an alarm trigger
input, be certain to use the dual diode set up shown earlier in this manual.
AFTER THE CONNECTION OF THE NEUTRAL START SAFETY WIRE AS
INDICATED IN ANY OF THE PREVIOUS ALTERNATE CONFIGURATIONS, THIS CIRCUIT
MUST BE TESTED FOR PROPER OPERATION.
Retest by following the steps outlined in the NEUTRAL START SAFETY TEST section of the manual.